Customization: | Available |
---|---|
Certification: | CE, ISO |
Place Style: | Horizontal |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. Public Utility:
No. |
Item |
Main Technical Parameter |
1 |
Pressure of Natural Gas |
10-15Kpa (pressure of Out let on main gas line) |
2 |
Calorific Value of LNG |
8400Kcal/ Nm3 |
3 |
Maximum Gas Consumption |
160Nm3/h |
4 |
Total Power of Motors |
250Kw |
5 |
Heating Power of Quenching Tank |
180Kw |
6 |
Compressed Air Consumption |
~0.8m3/h |
2. Configuration of the Complete Heat Treatment Line
NO. |
Item |
Qty |
1 |
Loading Roller Table before Solution Furnace |
3set |
2 |
Solution Furnace |
1set |
3 |
Quenching Tank Device |
1set |
4 |
Movable Roller Conveyor |
1set |
5 |
aging Furnace |
1set |
6 |
Cooling Chamber |
1set |
7 |
Unloading Roller Conveyor |
3set |
8 |
Combustion System |
1set |
9 |
Exhausting system |
1set |
10 |
Electrical Control System |
1set |
3. Main Technical Parameters
No. |
Item |
Technical parameters |
1 |
Energy Source |
Natural gas |
2 |
Calorific value |
8400Kcal/ Nm3 |
3 |
Power supply |
380V 50HZ |
4 |
Max. Gas consumption of solution furnace |
~120Nm3/h±10% |
5 |
Average gas consumption of solution furnace |
~100Nm3/h±10% |
6 |
Gas consumption of aging furnace |
~35 Nm3/h±10% |
7 |
Average gas consumption of aging furnace |
~30 Nm3/h±10% |
8 |
Size of stacker |
1800mm×1600mm×1600mm |
9 |
Loading capacity of each basket |
~200piece/stacker |
10 |
Cycle time |
~45min/basket (adjustable) |
11 |
Effective volume of quenching tank |
18m3 |
12 |
Heating power of quenching tank |
180KW |
13 |
Working temperature rate of quenching tank |
70-85 C |
14 |
Installation capacity of solution furnace |
155KW |
15 |
Installation capacity of aging furnace |
85KW |