1. Equipment Description
1.1 It is supplied for solution and aging treatment for aluminum cylinder block.
1.2Energy sources specification of customer workshop:
1)AC current 380V±15% , 50Hz
The installed capacity:230KVA
2)Air pressure- 0,4-0,5 MPa; purity grade 8.
The compressed air pipeline interface:1"
3)Water pressure :0,15-0,2 MPa.
4)Natural gas pressure outlet from GDS : 0,6 kg/cm².
Gas pipelineinterface:DN50
1.3 Equipment Configuration
1)Loading Table for solution furnace
2)Solution Furnace
3)Unloading Table for solution furnace
4)Air Quenching Chamber
5)Loading table for Aging furnace
6)Stacker
7)Aging Furnace
8)Unloading Table